翻訳と辞書
Words near each other
・ Milliken Memorial Community House
・ Milliken Mills High School
・ Milliken Mine
・ Milliken Park railway station
・ Milliken v. Bradley
・ Milliken v. Meyer
・ Milliken's tree theorem
・ Milliken, Colorado
・ Milliken, Ontario
・ Milliken, West Virginia
・ Milliken-Smith Farm
・ Milliken–Taylor theorem
・ Millikin University
・ Millimages
・ Milliman
Millimeter Anisotropy eXperiment IMaging Array
・ Millimeter cloud radar
・ Millimeter of mercury
・ Millimeter wave scanner
・ Millimeters, water gauge
・ Millimetre
・ Millin
・ Millinder
・ Milliner (surname)
・ Millinery Center Synagogue
・ Milling
・ Milling (machining)
・ Milling (surname)
・ Milling cutter
・ Milling yield


Dictionary Lists
翻訳と辞書 辞書検索 [ 開発暫定版 ]
スポンサード リンク

Millimeter Anisotropy eXperiment IMaging Array : ウィキペディア英語版
Millimeter Anisotropy eXperiment IMaging Array

The Millimeter Anisotropy eXperiment IMaging Array (MAXIMA) experiment was a balloon-borne experiment funded by the U.S. NSF, NASA and Department of Energy, and operated by an international collaboration headed by the University of California, to measure the fluctuations of the cosmic microwave background. It consisted of two flights, one in August 1998 and one in June 1999. For each flight the balloon was started at the Columbia Scientific Balloon Facility in Palestine, Texas and flew to an altitude of 40,000 metres for over 8 hours. For the first flight it took data from about 0.3 percent of the sky of the northern region near the Draco constellation. For the second flight, known as MAXIMA-II, twice the area was observed, this time in the direction of Ursa Major.
Initially planned together with the BOOMERanG experiment, it split off during the planning phase to take a less risky approach by reducing flying time as well as launching and landing on U.S. territory.
==Instrumentation==

A 1.3-metre primary mirror, along with a smaller secondary and tertiary mirror, was used to focus the microwaves onto the feed horns. The feed horns have spectral bands centred at 150, 240 and 420 GHz with a resolution of 10 arcminutes. A bolometer array consisting of 16 NTD-Ge Thermistors measured the incident radiation.
The detector array was cooled down to 100 mK via a four stage refrigeration process. Liquid nitrogen cooled the outer layer of radiation shielding and He-4 was used to cool the two other layers down to a temperature of 2-3 K. Finally liquid He-3 cooled the array down to operation temperature.
The shielding, together with the properties of the feed horns, gave a superb sensitivity of 40 μV/sec^1/2.
Two CCD cameras where used to provide accurate measurements of the telescope's orientation. The first wide-field camera pointed towards Polaris and gave a coarse orientation up to 15 arcminutes. The other camera was mounted in the primary focus and gives an accuracy of 0.5' for stars brighter than 6th magnitude, which in total gives an accurate position tracking of 10' for the telescope and hence of the microwaves.
For pointing the telescope, four motors were used.

抄文引用元・出典: フリー百科事典『 ウィキペディア(Wikipedia)
ウィキペディアで「Millimeter Anisotropy eXperiment IMaging Array」の詳細全文を読む



スポンサード リンク
翻訳と辞書 : 翻訳のためのインターネットリソース

Copyright(C) kotoba.ne.jp 1997-2016. All Rights Reserved.